FRONT CONNECTED CT Series

The CT Series consists of Valve Regulated batteries specially designed for telecommunications applications and demanding backup power systems. Featuring front terminal design, they provide easy installation and simplified maintenance, while their dimensions are compatible with standard 19” and 23” power cabinets. AGM technology and high reliability make them an ideal solution for critical continuous-operation applications.

× Battery image
  • Characteristics
  • Technology & Applications
  • FAQ

Characteristics

Front Terminal Design

Front-mounted terminals for easy installation and faster maintenance.

1

AGM Technology

Absorbent Glass Mat (AGM) separators with up to 99% gas recombination efficiency, eliminating the need for electrolyte refilling.

2

Long Service Life

Designed service life of up to 12 years under float charging conditions.

3

Low Self-Discharge

Extremely low self-discharge rate for maintaining performance during storage.

4

Optimized Cabinet Installation

Compatible with standard 19″ and 23″ battery cabinets, featuring a slim and tall profile for improved heat dissipation.

5

High Power Performance

Lead-calcium-tin alloy grids and computer-aided design for high discharge performance.

6

Easy Handling

Specially designed handles for easy transportation and safe installation.

7

Air Transport Certified

Compliant with the special provision A67 of the IATA/ICAO regulations, suitable for air transportation.

8
arrow_back
arrow_forward

The CT Series consists of Valve Regulated batteries specially designed for telecommunications applications and demanding backup power systems. Featuring front terminal design, they provide easy installation and simplified maintenance, while their dimensions are compatible with standard 19” and 23” power cabinets. AGM technology and high reliability make them an ideal solution for critical continuous-operation applications.

Model Nominal Voltage (V) Nominal Capacity (Ah) Length (mm) Width (mm) Height (mm) Total Height (mm) Terminal Weight (Kg)
CT12-50X 12 50 277 106 224 224 F11 17,3
CT12-50EX 12 50 277 106 224 224 F11 16,3
CT12-80X 12 80 564 115 189 189 F11 28,2
CT12-90X 12 90 395 110 286 293 F11/F19 30,5
CT12-100EX 12 100 508 110 223 238 F12 28,5
CT12-100SX 12 100 508 110 231 231 F18 31,9
CT12-100X 12 100 508 110 223 238 F15 32,5
CT12-105X 12 105 395 110 286 293 F18 35
CT12-105EX 12 105 395 110 286 293 F12 32,5
CT12-125EX 12 125 436 108 317 317 F12 36
CT12-125X 12 125 436 108 317 317 F15 38,8
CT12-150EX 12 150 548 105 316 316 F15 45,5
CT12-150X 12 150 548 105 316 316 F15 48,8
CT12-150Y-X 12 150 548 105 316 316 F15 45,5
CT12-150Z-X 12 150 552 110 288 295 F15 48,2
CT12-155X   155 551 110 316 316 F12 51,5
CT12-180EX 12 180 546 125 317 323 F15 53
CT12-180X 12 180 546 125 317 323 F15 56,4
CT12-180Y-X 12 180 546 125 317 323 F15 49,2
CT12-200X 12 200 558 125 315 223 MS 68,8
Technology
The CT Series is based on AGM (Absorbent Glass Mat) technology, where the electrolyte is absorbed into specialized fiberglass separators, providing enhanced safety, high reliability, and maintenance-free operation. The front terminal design allows easier access to the terminals, reducing installation and maintenance time in telecommunications systems and data centers. The fully sealed construction ensures safe operation and minimizes leakage risks.
Performance
CT batteries are designed to deliver stable and reliable power in demanding continuous-operation and backup energy applications. Their low internal resistance enables high discharge efficiency, while the extremely low self-discharge rate maintains operational readiness even after long periods of inactivity.

FAQ

  • Are they suitable for telecommunications installations? Yes. The CT Series is specifically designed for telecommunications applications and backup power systems.
  • Can they be installed in rack cabinets? Yes. Their dimensions are compatible with standard 19″ and 23″ cabinets.
  • Do they require maintenance? No. The series operates without the need for regular maintenance or electrolyte refilling.
  • Are they suitable for air transportation? Yes. They comply with the special provision A67 of the IATA/ICAO regulations for safe air transportation.

Applications

Power Supply Side Energy Storage

Data Centers

DATA_CENTER_SM

Electronic Equipment

Electrical Power Systems

Fire Protection Systems

Outdoor Telecommunications Installations

Distributed Energy Systems

Vending Machines

Technical Specifications

Model Nominal Voltage (V) Nominal Capacity (Ah) Length (mm) Width (mm) Height (mm) Total Height (mm) Terminal Weight (Kg)
CT12-50X 12 50 277 106 224 224 F11 17,3
CT12-50EX 12 50 277 106 224 224 F11 16,3
CT12-80X 12 80 564 115 189 189 F11 28,2
CT12-90X 12 90 395 110 286 293 F11/F19 30,5
CT12-100EX 12 100 508 110 223 238 F12 28,5
CT12-100SX 12 100 508 110 231 231 F18 31,9
CT12-100X 12 100 508 110 223 238 F15 32,5
CT12-105X 12 105 395 110 286 293 F18 35
CT12-105EX 12 105 395 110 286 293 F12 32,5
CT12-125EX 12 125 436 108 317 317 F12 36
CT12-125X 12 125 436 108 317 317 F15 38,8
CT12-150EX 12 150 548 105 316 316 F15 45,5
CT12-150X 12 150 548 105 316 316 F15 48,8
CT12-150Y-X 12 150 548 105 316 316 F15 45,5
CT12-150Z-X 12 150 552 110 288 295 F15 48,2
CT12-155X   155 551 110 316 316 F12 51,5
CT12-180EX 12 180 546 125 317 323 F15 53
CT12-180X 12 180 546 125 317 323 F15 56,4
CT12-180Y-X 12 180 546 125 317 323 F15 49,2
CT12-200X 12 200 558 125 315 223 MS 68,8